Astronomers detect faint signals that have travelled enormous distances. That made me wonder whether we could measure activity from a human brain without putting electrodes on the scalp. The answer depends on what “without touching” means. At roughly a centimetre from the head, it is possible. Across a room, it is a very different measurement problem.
What is a brain wave?
Neurons move charged ions across their membranes when they communicate. This produces changing electrical currents. When activity across many neurons is organised in time, a sensor can record a changing signal with rhythmic components. Those patterns are commonly called brain waves.
“Wave” here describes a pattern in a measurement. It does not mean the brain is broadcasting a useful radio signal into the distance. A scalp EEG records changing voltage differences; MEG records the weak magnetic fields associated with brain currents. Both signals reflect the activity of groups of neurons, not the action of one isolated cell. EEG and MEG review · NIH MEG overview
The size of the signal depends on where and how it is measured. An action potential changes the voltage across one neuron's membrane by roughly 100 millivolts. A scalp EEG amplifier measures voltage differences of roughly 5 to 100 microvolts. An NIH MEG system detects magnetic fields from brain activity around 10⁻¹⁴ tesla. These numbers use different units and describe different measurements; they are not successive readings of the same wave getting weaker. Neuron physiology · EEG instrumentation · NIH MEG overview
From ion flow to a signal outside the head
There is no single equation that exactly predicts a person's EEG from the activity of every neuron. Researchers use different models at different scales, each answering a narrower question.
At the cell level, the Hodgkin–Huxley model describes how changing sodium and potassium conductances produce an action potential. Cable theory describes how voltage changes spread along a neuron's dendrites and axon. These are models of electrical behaviour within cells. ATP-powered pumps maintain the ion gradients that make repeated signalling possible; the pump does not directly generate each spike. Hodgkin and Huxley's original paper · Cable spread · Ion gradients and ATP
At the sensor level, current-dipole and volume-conductor models connect activity in groups of aligned cortical neurons to voltages at scalp electrodes and magnetic fields near the head. They use electromagnetism and the electrical properties of tissue to predict what a sensor would measure. For EEG and MEG frequencies, these are generally quasi-static field calculations, not a model of brain waves radiating through space like radio transmissions. EEG and MEG field model · Volume conduction
The scale-up picture is this: ion movement produces currents in individual cells; synaptic input drives currents along the dendrites of many cortical pyramidal neurons; and the geometry and timing of those currents determine how much survives when their fields combine at a sensor. Currents pointing in different directions can partly cancel. EEG and MEG therefore do not count neurons that “fire together,” and a large signal does not identify one precise source by itself. MEG principles · EEG and MEG field model
Two idealised, identical current sources illustrate the principle: aligned, simultaneous contributions can add at a sensor, while opposite-facing or differently timed contributions can cancel partly or almost completely. Real neurons are not identical sources, and the result depends on their positions and on which EEG or MEG sensor is observing them. There is no universal number of synchronous neurons required for detection; estimates depend on source strength, geometry, sensor sensitivity, and noise. Study of source cancellation · Neural synchrony and MEG sensor responses
At the population level, neural mass models simplify many interacting neurons into a few variables. The Wilson–Cowan model, for example, studies how excitatory and inhibitory populations interact and can produce oscillations. Such models help test explanations for rhythms; they do not prove that one observed frequency has one fixed mental meaning. Wilson and Cowan's original paper
The brain also consumes chemical energy and produces heat. Neurovascular coupling links neural activity to changes in local blood flow and oxygen use. The Balloon model is used to study the delayed blood-oxygenation signal measured by fMRI; it is not a model of infrared heat emission or a substitute for EEG or MEG. Brain energy review · Balloon model paper
A simulation could vary the number, alignment, and timing of model current sources to show how a predicted sensor signal changes. It would also need a specified head model, sensor position, and noise level. That would illustrate the physics; it would not establish the sensitivity of a real device or show that a person's thoughts can be decoded. EEG and MEG field model
What do delta, alpha, and gamma mean?
The familiar Greek-letter names group oscillations by frequency, measured in hertz, or cycles per second. Approximate ranges often used for EEG are:
| Band | Approximate frequency |
|---|---|
| Delta | 0.5–4 Hz |
| Theta | 4–8 Hz |
| Alpha | 8–12 Hz |
| Beta | 12–30 Hz |
| Gamma | Above 30 Hz |
The boundaries vary somewhat between references. A single recording can contain activity in several bands at once, and the same frequency range can occur in different circumstances. Alpha activity, for example, is often prominent during relaxed wakefulness with eyes closed; that does not make every 10 Hz component proof of relaxation. Frequency is one feature of the signal, not a reading of a person's thoughts or mental state. EEG overview · Review of brain oscillations
Frequency also says nothing by itself about a signal's strength. Ten cycles per second tells us how quickly a pattern repeats. Microvolts or teslas tell us the magnitude of a measured electrical or magnetic signal. Confusing those quantities makes comparisons between brain activity and astronomical waves sound more revealing than they are.
Touching the scalp: EEG
Electroencephalography, or EEG, uses electrodes placed on the scalp to measure voltage differences. It gives a fast record of changing activity, but each electrode picks up a mixture of signals that has passed through the head. A channel cannot simply be read as the output of one neuron or one precise point in the brain. EEG instrumentation · EEG and MEG review
EEG is therefore a way to observe patterns at the scalp. Interpreting their source requires more than finding a frequency peak or seeing a large spike.
Close to the head, without scalp electrodes: MEG
Magnetoencephalography, or MEG, measures magnetic fields generated by brain currents. The sensors sit around the head, usually in a helmet-shaped arrangement, without needing to touch the scalp. NIH describes signals around 10⁻¹⁴ tesla in one of its MEG systems. This requires very sensitive instruments and control of background magnetic noise. NIH MEG overview
So a sensor about 1 cm from the scalp is close enough in principle for a properly designed MEG measurement. The key words are properly designed: the distance alone does not turn an ordinary magnetometer into a brain sensor. The sensor sensitivity, its orientation, head position, environmental interference, and often magnetic shielding all matter. NIH MEG overview · MEG methods review
Why a telescope is not the right analogy
A telescope is built to collect light or radio emission that propagates through space. EEG rhythms are not that kind of outgoing signal. The magnetic fields measured by MEG are extraordinarily weak near the head and drop rapidly with distance. Meanwhile, the environment adds magnetic signals from electronics, power lines, vehicles, and the Earth itself. Even if a detector notices a low-frequency fluctuation, it must still distinguish the brain from all those other sources. MEG principles · NIH comparison of magnetic fields
Sharing a frequency does not make two phenomena interchangeable. A 10 Hz EEG rhythm, a 10 Hz sound wave, and a 10 Hz gravitational wave repeat at the same rate, but their physical carriers and detection methods differ. The National Radio Astronomy Observatory explains why very low frequencies and confusion between nearby sources defeat the idea of resolving individual human brain activity with a satellite radio telescope array. NRAO explanation
The answer I arrived at
The brain produces measurable electrical and magnetic activity. We can record it with electrodes on the scalp, or measure its magnetic field without scalp contact when sensitive sensors are held close to the head. Neither result implies that we can read an individual brain from a large distance. One centimetre without contact is a real measurement setting; “from afar” is a different claim.