AI & ML
Quality-Control Policies Shape Model Behaviour in Computational Pathology
arXiv eess.IV0 views
arXiv:2611.28179v1 Announce Type: new Abstract: Quality-control policies determine which image regions are used by computational pathology models, but their effects are difficult to isolate when quality estimation and input selection are coupled. We make these policies explicit, configurable and testable. We introduce PathQC-3C, comprising 1,661 densely annotated regions from 1,194 haematoxylin and eosin whole-slide images across 32 cancer/tissue categories, and TileNet, a framework that separates dense tissue/background/artefact estimation from task-specific input-selection policies. We evaluated the default predictor across three held-out cohorts and against harmonised quality-control comparators, assessed policy decisions in a blinded single-pathologist audit, and tested alternative policies in three downstream settings. In retrospective CAMELYON16 multiple-instance learning, background-aware selection improved the pooled out-of-fold area under the receiver operating characteristic curve from 0.758 to 0.839 compared with random sampling from the same exhaustive candidate pool under a fixed tile budget. In weak-label lung classification, strict artefact exclusion reduced the pre-matching candidate pool by approximately 43%, with small metric-dependent differences after matching training-set size and patient contribution. PathQCAug, which composites real artefact components during tumour-stroma model adaptation, improved macro Dice on high-artefact tiles under severe held-out composited artefacts across three training seeds and outperformed random-erasing and clean-tissue controls. Separating quality estimation from policy execution provides an auditable way to control which image content enters computational pathology models; the appropriate policy is task specific, and clinical utility remains to be established.
Source:https://arxiv.org/abs/2611.28179PreviousThe UNIFESP Chest CT Fatty Liver DatasetNextBeyond Outlier Rejection: Transient-Aware Reconstruction of Multi-Stack MRI
Related posts

LLM-as-a-Judge Position Bias: Claude Flipped 103 of 400 Verdicts
0dev.to
PSNR rewards blur: what fine-tuning a video upscaler taught us about measuring quality
0dev.to
CCDV-P Exam: How I'm Preparing for the Claude Certified Developer – Professional
0dev.to
ISC Stormcast For Wednesday, November 25th, 2026 https://isc.sans.edu/podcastdetail/10194, (Wed, Nov 25th)
0SANS ISC
Prístupnosť webu: 7 chýb, ktoré vylúčia časť vašich zákazníkov
0dev.to UX
22 non-game apps launched in the last 90 days already make an estimated $10K+/month
0dev.to Data