Three numbers decide whether a panel build fits on the first try: the cutout, the fuse holder size, and the inlet series. They are also the three that get ordered wrong most often, because the catalogue shows a photo of the front and says nothing about the panel.

Cutout: 30x22 vs 19x13

The KCD-series numbers people quote are not the switch size. They are the panel hole:

Series Cutout Typical rating Bezel
KCD1 19 x 13 mm 6-10 A ~21 x 15 mm
KCD4 30 x 22 mm 16-20 A ~33 x 25 mm

Three things that go wrong even when the cutout is correct:

  1. Panel thickness. Snap-in legs are moulded for roughly 0.8-3 mm. A 4 mm panel will not let the legs spring back and the switch sits proud; a 0.6 mm sheet flexes and the switch rocks in the hole. The fix is a screw-mount variant or a backing plate, not a bigger cutout.
  2. Tolerance. Cut 30.0 x 22.0 +0.2/-0 mm. A laser-cut 29.8 mm hole will crack the retaining clips on first insertion, and that crack does not show until the switch is under load.
  3. Corner radius. The hole needs square corners with a small radius, not a punched round hole with filed flats. The bezel lip covers 1.5 mm per side; anything more and you see daylight.

If you are replacing a switch in an existing panel, measure the hole, not the old switch. The old bezel tells you nothing about the cutout.

Fuse holders: 5x20 vs 6.3x32

Both are cartridge fuses. The first number is the fuse, not the holder: 5 mm diameter by 20 mm long, or 6.3 mm by 32 mm.

  • 5x20 is the electronics size. Panel holders in this size are generally rated around 6.3-10 A at 250 V, with limited breaking capacity. It is the right choice for control circuits, small PSUs and anything under about 5 A continuous.
  • 6.3x32 is the industrial size. 16 A at 250 V is routine, higher breaking capacity, and the ceramic body survives a real fault without shattering. This is what belongs downstream of a 16 A panel switch.

The mistake I see most: a 16(4)A rocker switch with a 5x20 holder on the same panel, because the holder was cheaper. The switch is fine; the holder's contacts and the fuse's interrupting rating are the weak link. Match the holder to the load, not to the switch's outside number.

Also check the holder's own contact resistance: a tired panel fuse holder adds 20-50 mΩ in series with everything else, which shows up as a hot spot long before the fuse blows.

Inlets: C14 vs C20 (and why C16 is not the answer)

IEC 60320 inlets are keyed by current, and the keyway is physical, so you cannot mis-mate them:

Inlet Rated Mates with Notes
C14 10 A / 250 V C13 cord The default for most equipment
C16 10 A / 250 V, 120 C C15 cord Hot-condition variant, not a 16 A part
C20 16 A / 250 V C19 cord Wider blades, larger body

So a 16 A product cannot use a C14 inlet. It needs C20, or it needs to stay under 10 A. The C16 trap catches people who read "16" as amps: it is a temperature rating, for kettles and heaters, and it is still a 10 A inlet.

The 3-pin rocker switch: which pin is ground?

None of them. A rocker switch has no protective earth terminal, and no switch pin should ever be tied to chassis earth as a current path.

The three pins on an illuminated rocker are:

  • Two switch terminals (line in, load out).
  • One lamp return for the internal neon or LED, which is why a 3-pin illuminated switch needs a neutral even though it sits in the live leg.

You can identify them in ten seconds with a meter on continuity, switch OFF: the pair that beeps is the lamp circuit, because the lamp and its series resistor sit permanently across those two pins. The remaining pair is the switch contact, which only beeps with the switch ON.

If a wiring diagram shows a pin going to earth, that pin is on the inlet or the terminal block, not the switch.

I work with a manufacturer of these parts, so treat this as field notes. The same numbers, with the tables side by side, are collected on this answer page, including the 3-pin rocker pinout test.