Both switches are 1U, both present 32 ports in the front panel, and both are sold under names that look interchangeable. They are not. The Mellanox SN2700 is a Spectrum-1 platform with 32 QSFP28 cages and a hard ceiling of 100GbE per port. The Mellanox SN3700 is a Spectrum-2 platform with 32 QSFP56 cages and 200GbE per port. If every link in your fabric terminates at 100G, the SN2700 does the same job for less power and less money. If you need 200G uplinks, a 42MB buffer, or a platform that still has a support life ahead of it, the SN3700 is the correct answer. Everything below is the detail behind that split.
What the SN2700 Actually Is
The SN2700 is built on the Spectrum-1 ASIC and exposes 32 QSFP28 ports running 10, 25, 40, 50 or 100GbE. Switching capacity is 6.4Tb/s bidirectional, forwarding rate 4.76Bpps, and port-to-port latency is quoted at 300ns in cut-through mode. The packet buffer is 16MB, fully shared rather than carved into per-port slices — which is the reason this switch absorbs many-to-one incast and storage microbursts better than segmented-buffer boxes in the same class. Control plane is an Intel x86 dual-core at 1.40GHz with 8GB of DDR3, four hot-swap fans in an N+1 arrangement, and two hot-swap power supplies. Typical draw is around 130W with passive copper, up to roughly 180W loaded with optics. Chassis depth is 686mm.
One practical consequence of the design: the SN2700 family is end-of-life as a product line. That does not make it a bad switch — it makes it a stable, well-documented switch with no remaining roadmap. Firmware still installs, the feature set is frozen and predictable, and the secondary market is deep. If your fabric already runs SN2700 units, adding more of the same model is usually cheaper and less risky than introducing a second silicon generation into the same leaf layer. A current unit is listed here for the SN2700 32-port QSFP28 build.
What the SN3700 Actually Is
The SN3700 moves to Spectrum-2 and QSFP56 cages, which is what unlocks 200GbE per port. Port speeds span 10, 25, 40, 50, 100 and 200GbE. Throughput stays at 6.4Tb/s on the 200G model because 32 ports at 200G is the same aggregate as 32 ports at 100G doubled — the difference is where the bandwidth sits, not how much of it exists. Forwarding rate rises to 8.33Bpps. Latency is 425ns, higher than the SN2700's 300ns because the pipeline is deeper and the feature set is larger. The packet buffer is 42MB, more than two and a half times the SN2700's, and the CPU is a quad-core x86 at 2.20GHz.
Two details matter more than the headline numbers. First, chassis depth drops to 559mm — 127mm shallower than the SN2700, which is the difference between fitting and not fitting in a shallow rack or a two-post telecom frame. Second, global power consumption rises to about 250W, nearly double. In a 40-rack deployment that power delta becomes a real number on the PDU budget, and it is the single most under-estimated cost when teams move from 100G to 200G switching. A 200GbE build with the reverse-airflow option is listed as SN3700-VS2R 32-port QSFP56, and the 100GbE variant sits here as SN3700-CS2F 32-port QSFP28.
SN2700 vs SN3700 Side by Side
| Specification | SN2700 | SN3700 (200GbE) | SN3700C (100GbE) |
|---|---|---|---|
| ASIC | Spectrum-1 | Spectrum-2 | Spectrum-2 |
| Connector | 32 × QSFP28 | 32 × QSFP56 | 32 × QSFP28 |
| Max speed per port | 100GbE | 200GbE | 100GbE |
| Throughput | 6.4Tb/s | 6.4Tb/s | 3.2Tb/s |
| Forwarding rate | 4.76Bpps | 8.33Bpps | 4.76Bpps |
| Latency (cut-through) | 300ns | 425ns | 425ns |
| Packet buffer | 16MB shared | 42MB shared | 42MB shared |
| Chassis depth | 686mm | 559mm | 559mm |
| Typical power | ~130W | ~250W | ~242W |
| Fans | 4, N+1 | 6, N+1 | 4, N+1 |
| Product status | End of life | In lifecycle | In lifecycle |
SN3700C Is Not an SN3700 — Read the Letter Before the Number
This is where most sourcing mistakes happen. The SN3700C is a Spectrum-2 switch with 32 QSFP28 cages, 3.2Tb/s throughput and a 100GbE ceiling. It is a different product with the same family name. It is not a 200G switch that has been limited by firmware, and you cannot unlock 200G on it later.
NVIDIA's ordering codes carry the speed class in the letter before the S. In MSN2700-CS2F, the C means 100GbE. In MSN3700-VS2R, the V means 200GbE. A B in that position is the 40GbE build, and a W is 400GbE on later generations. The trailing letter is airflow, not performance: F for front-to-back, R for reverse. So SN3700-CS2F and SN3700-VS2R are not near-equivalents — one is a 100G box with forward airflow, the other is a 200G box with reverse airflow. Two independent variables in one string.
Airflow Decides Whether the Switch Belongs in Your Rack
Airflow is set by the fan and power-supply modules, not by the chassis, and it cannot be changed in software. A power-to-connector (P2C, forward) unit pulls cold air in at the PSU side and exhausts at the port side. A connector-to-power (C2P, reverse) unit does the opposite. Put the wrong direction in a hot aisle and you recirculate exhaust into the intake, which shows up months later as thermal throttling and fan failures rather than as an obvious fault.
Both platforms offer both directions, which is why the same model appears under several part numbers. When you specify a switch by model name only, you are leaving the airflow to whoever picks the unit. Specify the full OPN, or state the direction explicitly and ask for the fan and PSU colour coding to be confirmed against it. This single check eliminates the most common reason a delivered switch has to be returned.
Breakout, Cabling and the 200G Transition
On the SN2700, each QSFP28 port can be split into two 50GbE or four 25GbE links, which is how a 32-port switch serves a full rack of 25G servers without a second tier. On the SN3700, QSFP56 ports split to 2×100GbE as well as the lower rates, so a single 200G port can feed two 100G leaf-facing links. Passive copper DAC reaches roughly three metres at these rates; beyond that you move to active optical cables or optics, and the optics bill is frequently larger than the switch bill in a 200G refresh.
400GbE is not available on either platform. Teams planning a 400G spine should be looking at Spectrum-3 hardware, and should treat an SN3700 purchase as a 100G/200G decision rather than a stepping stone to 400G. Where the SN3700 genuinely earns its place is as a 200G spine over 100G leaves: 32 ports of 200G gives 16 leaf connections with no oversubscription, using dual-port 100GbE ConnectX-5 adapters at the server end and QSFP56 to 2×QSFP28 fan-out at the spine.
Network OS: The Decision That Outlives the Hardware
Both switches run ONIE, which means the operating system is a separate decision from the box. NVIDIA Onyx (MLNX-OS) gives you the vendor CLI and the vendor feature track. Cumulus Linux gives you a Linux-based stack with standard routing daemons. SONiC gives you an open, container-based stack that many large operators standardise on. The hardware does not care; your team's operational muscle memory does.
Two things to confirm before committing to a batch. First, which NOS the units were originally ordered with — the OPN records it, and an ONIE unit with no licence arrives with no OS at all. Second, whether the software subscription attached to those units is transferable. Vendor NOS subscriptions are frequently tied to the original purchaser and do not follow the hardware, which turns a cheap switch into an expensive one after the first support renewal. Ask the question before the invoice, not after.
How to Decide in Four Questions
- Is any link in this fabric faster than 100G? If no, the SN2700 covers it at lower power and lower cost. If yes, the SN3700 is the only option of the two.
- How deep is the rack? Below 600mm usable depth, the SN2700's 686mm chassis will not close the door. The SN3700's 559mm will.
- What does the buffer have to absorb? Storage backends, NVMe-over-Fabrics and AI east-west traffic produce incast that a 16MB buffer handles less gracefully than a 42MB one. Pure web-tier traffic does not care.
- How long does this fabric need to stay in service? A five-year horizon argues for the platform still in lifecycle. A two-year lab or a spare-parts pool argues for matching what is already installed.
What to Verify Before You Commit
Ask for five facts about the exact unit, not the model: the full OPN, the airflow direction, the installed NOS and firmware level, the port count actually passing traffic, and the error counters on the uplinks. A switch that links but accumulates CRC errors on two ports is a switch with a bad cage or a bad cable, and it will pass a power-on test. Front-panel photos of the specific serial number, plus a console capture of the firmware version, settle most of this in one exchange.
For fabrics that need more than 32 ports at the spine, the same silicon family continues in the SN3800 64-port 100GbE 2U build and, at 200G density, the SN4600 64-port 200GbE 2U build. Matching generation across leaf and spine keeps the feature set consistent and the spare-parts inventory small.
Frequently Asked Questions
Can an SN2700 run at 200GbE?
No. The QSFP28 cages and the Spectrum-1 ASIC cap the port at 100GbE. No firmware release changes this. 200GbE requires QSFP56 cages and Spectrum-2 silicon, which means the SN3700 or a later generation.
Is the SN3700C a 200G switch?
No. The SN3700C is the 100GbE member of the SN3700 family: 32 QSFP28 ports, 3.2Tb/s throughput, 100GbE ceiling. It shares the Spectrum-2 silicon and the 42MB buffer but not the port speed. Check the OPN letter — C for 100G, V for 200G.
Can I mix SN2700 and SN3700 in the same fabric?
Yes, at 100GbE. Both run standard Ethernet, VXLAN and RoCE, and they interoperate at 100G over QSFP28. The SN3700 will not negotiate 200G with an SN2700 port, and the two platforms have different latency and buffer characteristics, so keep a given tier homogeneous where you can.
Do these switches ship with transceivers or cables?
No. Optics, DAC and AOC are separate line items and are coded to the port type — QSFP28 for the SN2700 and SN3700C, QSFP56 for the 200G SN3700. Confirm the optic or cable part number against the switch port type before ordering; this is the second most common mismatch after airflow.
Which one holds its value better?
The SN3700, because it is still in lifecycle and covers both 100G and 200G roles. The SN2700's value is now driven entirely by installed base — buyers who need spares for an existing SN2700 fabric pay for compatibility, not for capability.
Need a specific build? Send the model list — full OPN, airflow direction and quantity — and we confirm availability per model at zhongxindata.hk or on WhatsApp +86 13068616914.
Published by Zhongxin Data | November 2026